{"id":32021,"date":"2026-11-14T11:58:47","date_gmt":"2026-11-14T11:58:47","guid":{"rendered":"https:\/\/cngrandmachinery.com\/?p=32021"},"modified":"2026-11-19T07:41:40","modified_gmt":"2026-11-19T07:41:40","slug":"emulsification-mixer-cream-separation","status":"publish","type":"post","link":"https:\/\/cngrandmachinery.com\/fr\/blog\/emulsification-mixer-cream-separation\/","title":{"rendered":"D\u00e9pannage des m\u00e9langeurs \u00e9mulsifiants : pourquoi les \u00e9mulsions cr\u00e9meuses se s\u00e9parent-elles ?"},"content":{"rendered":"\n<style>\nbody.postid-32021 .gm-et-table{max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch}\nbody.postid-32021 .gm-et-table table{width:100%;min-width:560px;border-collapse:collapse}\nbody.postid-32021 .gm-et-table th,body.postid-32021 .gm-et-table td{vertical-align:top;padding:12px 14px;word-break:normal;overflow-wrap:normal}\nbody.postid-32021 .gm-et-table th{background:#f3f4fa;color:#24265d;text-align:left}\nbody.postid-32021 .gm-et-photo img{display:block;max-width:680px;width:100%;height:auto;margin:auto;border-radius:16px}\nbody.postid-32021 .gm-et-scroll-hint{display:none;font-size:13px;color:#667085;margin:8px 0}\n\n@media(max-width:767px){body.postid-32021 .gm-et-scroll-hint{display:block}}\n\nbody.postid-32021 .gm-et-photo figcaption{font-size:14px;line-height:1.6;color:#667085;margin-top:10px}\nbody.postid-32021 .gm-et-flow{margin:28px 0;padding:24px;border:1px solid #e4e7ec;border-radius:18px;background:#fafaff}\nbody.postid-32021 .gm-et-flow>figcaption{font-size:20px;font-weight:650;color:#24265d;line-height:1.4;margin:0 0 24px}\nbody.postid-32021 .gm-et-flow-steps{list-style:none;margin:0;padding:0}\nbody.postid-32021 .gm-et-flow-steps>li{position:relative;margin:0 0 32px;padding:18px;border:1px solid #cdcde5;border-radius:12px;background:#fff}\nbody.postid-32021 .gm-et-flow-steps>li:not(:last-child)::after{content:\"\u2193\";position:absolute;bottom:-30px;left:calc(50% - 12px);width:24px;text-align:center;color:#3b397d;font-size:23px;line-height:28px}\nbody.postid-32021 .gm-et-flow-steps>li:last-child{margin-bottom:0}\nbody.postid-32021 .gm-et-flow strong{display:block;font-size:16px;line-height:1.5;color:#24265d}\nbody.postid-32021 .gm-et-flow p{margin:8px 0 0;font-size:15px;line-height:1.6}\nbody.postid-32021 .gm-et-flow-branches{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:12px;margin-top:14px}\nbody.postid-32021 .gm-et-flow-branches>div{min-width:0;padding:14px;border:1px solid #ddddec;border-radius:10px;background:#f5f5fb}\nbody.postid-32021 .gm-et-flow-branches span{font-size:14px;font-weight:650;color:#34347b}\nbody.postid-32021 .gm-et-flow-note{color:#526077}\n@media(max-width:600px){body.postid-32021 .gm-et-flow{padding:16px}body.postid-32021 .gm-et-flow-steps>li{padding:14px}body.postid-32021 .gm-et-flow-branches{grid-template-columns:minmax(0,1fr)}}\nbody.postid-32021 .gm-bp-cover img{object-fit:contain!important}\nbody.postid-32021 .gm-et-table:focus-visible{outline:2px solid #2d66d8;outline-offset:3px}\nbody.postid-32021 .gm-et-quick-list li{margin-bottom:12px}\nbody.postid-32021 .gm-bp-content [id]{scroll-margin-top:var(--gm-bp-top,120px)}\n<\/style>\n<p class=\"gm-bp-lead wp-block-paragraph\"><strong>A cream can look uniform in the mixer and separate after cooling or filling.<\/strong> Check the formulation, droplet structure and processing history before treating higher mixer speed as the solution.<\/p>\n<p class=\"wp-block-paragraph\">An <strong>emulsification mixer<\/strong> helps form and process an emulsion, while lasting physical stability also depends on ingredient compatibility, circulation, temperature history and downstream handling. This guide focuses on emulsion-based cosmetic creams and lotions and gives a framework for planning an investigation.<\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-quick-troubleshooting-guide\">Quick Troubleshooting Guide<\/h2>\n<p class=\"wp-block-paragraph\">Record the visible change and when it first appeared. Use comparable retained samples and batch records to choose the next check:<\/p>\n<ul class=\"gm-et-quick-list\">\n<li><strong>Layers, oiling out or watery release:<\/strong> <a href=\"#gm-et-identify-the-defect-before-naming-the-cause\">identify the separation mechanism<\/a>, then review formulation and storage history.<\/li>\n<li><strong>Graininess that appears during cooling:<\/strong> <a href=\"#gm-et-follow-the-product-through-heating-addition-and-cooling\">compare phase preparation and the temperature\u2013time history<\/a>.<\/li>\n<li><strong>Foam or bubbles:<\/strong> <a href=\"#gm-et-treat-vacuum-deaeration-as-an-air-control-step\">trace air entry and the deaeration stage<\/a> separately from oil\u2013water stability.<\/li>\n<li><strong>Different results across the vessel:<\/strong> <a href=\"#gm-et-high-shear-must-work-with-whole-batch-circulation\">check circulation, ingredient incorporation and sampling consistency<\/a>.<\/li>\n<\/ul>\n<div class=\"gm-bp-callout\"><p>Choose a hypothesis before changing settings. Define the comparison sample, sampling method and acceptance criteria; then follow the product through cooling, transfer, filling and storage.<\/p><\/div>\n<h2 class=\"wp-block-heading\" id=\"gm-et-identify-the-defect-before-naming-the-cause\">Identify the Defect Before Naming the Cause<\/h2>\n<p class=\"wp-block-paragraph\">In an oil-in-water emulsion, oil droplets sit within a continuous water phase; water-in-oil emulsions reverse those roles. A visible layer can develop through different mechanisms.<\/p>\n<p class=\"gm-et-scroll-hint\">Swipe horizontally to view all columns.<\/p>\n<div class=\"gm-et-table\" role=\"region\" tabindex=\"0\" aria-label=\"Emulsion separation mechanisms\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Change<\/th>\n<th scope=\"col\">What happens<\/th>\n<th scope=\"col\">Useful distinction<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Creaming or sedimentation<\/td>\n<td>Droplets migrate upward or downward, creating a concentration difference.<\/td>\n<td>Movement does not necessarily mean the droplets have fused.<\/td>\n<\/tr>\n<tr>\n<td>Flocculation<\/td>\n<td>Droplets form clusters while retaining individual boundaries.<\/td>\n<td>A cluster is different from one larger droplet.<\/td>\n<\/tr>\n<tr>\n<td>Coalescence<\/td>\n<td>Separate droplets merge into larger ones.<\/td>\n<td>This changes droplet structure, rather than merely redistributing droplets.<\/td>\n<\/tr>\n<tr>\n<td>Serum release or apparent \u201cweeping\u201d<\/td>\n<td>Liquid becomes visibly separated from the structured product.<\/td>\n<td>Appearance alone cannot distinguish network changes from other separation mechanisms.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"wp-block-paragraph\">An oily-looking top layer is therefore an observation, not a complete diagnosis. Microscopy and appropriately measured droplet-size distributions can help distinguish concentrated droplets, clusters and droplet growth.<\/p>\n<p class=\"wp-block-paragraph\">Other defects need separate consideration. <strong>Graininess<\/strong> may involve undispersed powder or crystallized material. <strong>Foam<\/strong> contains gas bubbles, not just liquid droplets. Ostwald ripening\u2014growth involving molecular transfer between droplets\u2014and phase inversion are additional possibilities in suitable systems, but neither should be diagnosed from a surface photograph.<\/p>\n<p class=\"wp-block-paragraph\">These mechanisms can also coexist. A batch can contain air while its emulsion structure changes. Classifying one defect should not automatically close the investigation into another.<\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-formulation-creates-the-conditions-for-stability\">Review Formulation and the Continuous Phase<\/h2>\n<h3 class=\"wp-block-heading\" id=\"gm-et-making-droplets-and-protecting-droplets-are-different-jobs\">Making droplets and protecting droplets are different jobs<\/h3>\n<p class=\"wp-block-paragraph\">Breaking a larger droplet into smaller droplets creates more oil\u2013water interfacial area. A suitable emulsifier system must stabilize that interface while the surrounding formulation supports the intended product structure.<\/p>\n<p class=\"wp-block-paragraph\">This explains why \u201cfiner\u201d does not automatically mean \u201cstable.\u201d Small droplets with inadequate interfacial protection can still change after processing. Conversely, a thick-looking cream can conceal changes in its droplet population.<\/p>\n<p class=\"wp-block-paragraph\">For troubleshooting, review the complete formulation rather than only the emulsifier percentage. Oil composition, dispersed-phase fraction, emulsifier combinations and thickener compatibility can all change the system being processed. An ingredient substitution may preserve the label description while changing the material\u2019s actual behavior.<\/p>\n<h3 class=\"wp-block-heading\" id=\"gm-et-the-continuous-phase-also-matters\">The continuous phase also matters<\/h3>\n<p class=\"wp-block-paragraph\">Many creams obtain their texture from more than dispersed droplets. Polymers and structures involving surfactants, fatty alcohols or wax components may contribute to their rheology\u2014the way they flow and recover after deformation.<\/p>\n<p class=\"wp-block-paragraph\">A practical distinction follows: <strong>loss of viscosity and droplet coalescence are not interchangeable findings.<\/strong> Measure texture-related changes and droplet-related changes separately, then consider whether they are connected.<\/p>\n<p class=\"wp-block-paragraph\">Water quality and dissolved ingredients deserve attention too. Research on two non-ionic alkyl polyglucoside emulsifier systems found that changing the water\u2019s ionic composition altered viscosity and viscoelastic behavior. The result was formulation-dependent; it does not mean that every electrolyte destabilizes every cream.<a href=\"#gm-et-ref-1\">[1]<\/a><\/p>\n<p class=\"wp-block-paragraph\">Check pH against the approved formulation and compare measurements made under the same method and temperature. For systems containing ionizable ingredients, a pH change may alter interactions or thickening behavior. There is no single corrective pH suitable for all cosmetic emulsions.<\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-separate-the-functions-inside-an-emulsification-system\">Separate the Functions of an Emulsification Mixer<\/h2>\n<p class=\"wp-block-paragraph\">An integrated machine may perform several operations, but those operations solve different problems.<\/p>\n<p class=\"gm-et-scroll-hint\">Swipe horizontally to view all columns.<\/p>\n<div class=\"gm-et-table\" role=\"region\" tabindex=\"0\" aria-label=\"Emulsification mixer functions\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Function<\/th>\n<th scope=\"col\">Main contribution<\/th>\n<th scope=\"col\">What it does not establish<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>High-shear homogenization<\/td>\n<td>Local deformation, dispersion and droplet breakup under suitable conditions<\/td>\n<td>Long-term stability by itself<\/td>\n<\/tr>\n<tr>\n<td>Bulk agitation<\/td>\n<td>Movement of material through the vessel and distribution of additions<\/td>\n<td>Identical treatment at every location without process verification<\/td>\n<\/tr>\n<tr>\n<td>Heating and cooling<\/td>\n<td>Control of the thermal stages required by the formulation<\/td>\n<td>One temperature profile suitable for all creams<\/td>\n<\/tr>\n<tr>\n<td>Vacuum processing<\/td>\n<td>Removal of entrained air under suitable operating conditions<\/td>\n<td>Correction of an incompatible emulsifier system<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"wp-block-paragraph\">For an equipment example, GRAND\u2019s <a href=\"https:\/\/cngrandmachinery.com\/product\/100l-vacuum-emulsifying-mixer\/\">CB100 vacuum emulsifying mixer<\/a> lists a <strong>100 L working capacity<\/strong> and a <strong>160 L main vessel<\/strong>, together with separate homogenizing and slow-agitation functions, vacuum mixing, and heating and cooling.<\/p>\n<figure class=\"gm-et-photo\">\n<img class=\"wp-image-29463\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe2-800x800.webp\" alt=\"GRAND CB100 100 L vacuum emulsifying mixer with the stainless steel mixing vessel open.\" srcset=\"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe2-800x800.webp 800w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe2-430x430.webp 430w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe2-150x150.webp 150w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe2-700x700.webp 700w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe2-300x300.webp 300w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe2-768x768.webp 768w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe2.webp 1000w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption><em>GRAND CB100 vacuum emulsifying mixer with the mixing vessel open.<\/em><\/figcaption><\/figure>\n<p class=\"wp-block-paragraph\">The broader <a href=\"https:\/\/cngrandmachinery.com\/emulsifying-mixer\/\">emulsifying mixer range<\/a> provides equipment context. A troubleshooting investigation still needs the actual formulation, batch history and configuration of the machine in use.<\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-high-shear-must-work-with-whole-batch-circulation\">Check High Shear and Whole-Batch Circulation<\/h2>\n<p class=\"wp-block-paragraph\">In a rotor\u2013stator mixer, material is exposed to intense local deformation around a rotating element and a stationary workhead. Silverson\u2019s technical explanation describes how material is drawn into the workhead, sheared and recirculated through the vessel.<a href=\"#gm-et-ref-5\">[5]<\/a><\/p>\n<p class=\"wp-block-paragraph\">Local processing and vessel-wide circulation are related but different. A powerful workhead cannot demonstrate that every part of a viscous batch has received equivalent treatment.<\/p>\n<p class=\"wp-block-paragraph\">Calvo and colleagues studied cosmetic emulsions at different dispersed-phase concentrations and examined both impeller tip velocity and pumping capacity. Their findings support considering droplet deformation and circulation together, rather than treating rotational speed as the only relevant variable.<a href=\"#gm-et-ref-2\">[2]<\/a><\/p>\n<p class=\"wp-block-paragraph\">For example, if samples from approved vessel sampling points differ, investigate circulation, incorporation of additions and sampling consistency before assuming that the entire batch needs more shear. If samples agree initially but change during storage, the investigation must extend beyond immediate uniformity.<\/p>\n<p class=\"wp-block-paragraph\">The same reasoning applies when scaling up. Matching rpm does not match rotor dimensions, vessel geometry, material flow or cooling history. A larger batch needs a demonstrated process transfer, not simply the smaller batch\u2019s settings copied onto a different machine.<\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-follow-the-product-through-heating-addition-and-cooling\">Review Heating, Ingredient Addition and Cooling<\/h2>\n<h3 class=\"wp-block-heading\" id=\"gm-et-before-and-during-emulsification\">Before and during emulsification<\/h3>\n<p class=\"wp-block-paragraph\">The state of each phase matters when the phases meet. Where the approved process requires melted waxes, hydrated polymers or dissolved ingredients, incomplete preparation introduces a different starting material into the emulsification stage.<\/p>\n<p class=\"wp-block-paragraph\">Record the <strong>actual product temperatures<\/strong>, not only jacket settings. Also compare the order, location and timing of additions. A late ingredient addition can change composition locally before it has dispersed through the batch.<\/p>\n<p class=\"wp-block-paragraph\">Do not interpret every visible particle as an oil droplet. A powder agglomerate calls for a different investigation from droplet coalescence.<\/p>\n<h3 class=\"wp-block-heading\" id=\"gm-et-during-cooling\">During cooling<\/h3>\n<p class=\"wp-block-paragraph\">Some cream structures continue developing after the principal emulsification step. Cooling can change the organization of wax and fatty-alcohol components, while agitation acts on a product whose consistency is also changing.<\/p>\n<p class=\"wp-block-paragraph\">In a 2024 study of a particular emulsion cream, introducing a holding stage during cooling improved stability under the tested conditions. Additional shear during that stage affected the developing structure, and the result depended on the temperature at which it was applied.<a href=\"#gm-et-ref-3\">[3]<\/a><\/p>\n<p class=\"wp-block-paragraph\">That study does <strong>not<\/strong> establish a universal cooling temperature or prove that agitation during cooling is always harmful. Its practical significance is that the post-emulsification stage can deserve as much investigation as the initial homogenization stage.<\/p>\n<p class=\"wp-block-paragraph\">Compare the complete temperature\u2013time history of acceptable and affected batches. \u201cBoth finished at the same temperature\u201d is incomplete: one batch may have cooled steadily while another experienced a long hold or a different mixing schedule.<\/p>\n<p class=\"wp-block-paragraph\">Where graininess appears only after cooling, retain samples from before and after the change. That timing helps focus the investigation on what developed during cooling, without prematurely deciding which ingredient or mechanism caused it.<\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-treat-vacuum-deaeration-as-an-air-control-step\">Treat Vacuum Deaeration as an Air-Control Step<\/h2>\n<p class=\"wp-block-paragraph\">Vacuum can assist with removing entrained air. IKA\u2019s 2023 cosmetic-formulation brochure describes a laboratory reactor system combining heating, cooling, mixing, dispersing and vacuum control, and specifically lists vacuum for de-foaming during mixing.<a href=\"#gm-et-ref-4\">[4]<\/a><\/p>\n<p class=\"wp-block-paragraph\">The distinction matters because a gas bubble and an oil droplet are different dispersed structures. A product can become less foamy without its oil\u2013water interface becoming more stable.<\/p>\n<p class=\"wp-block-paragraph\">If the dominant defect is bubbles, investigate when air entered: ingredient addition, surface agitation, transfer or filling. Review the timing of the vacuum stage and the condition of the system through your facility\u2019s approved operating and maintenance procedures.<\/p>\n<p class=\"wp-block-paragraph\">Compare observations before and after deaeration using consistent methods. Improvement in visible bubbles supports an air-related explanation for that defect; it does not prove that all other quality attributes have improved.<\/p>\n<p class=\"wp-block-paragraph\">If a distinct oil or water layer remains after the bubble problem is addressed, return to the emulsion investigation. \u201cMore vacuum\u201d is not a substitute for identifying the remaining mechanism.<\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-build-a-testable-investigation-not-a-list-of-guesses\">Build a Testable Investigation<\/h2>\n<p class=\"wp-block-paragraph\">Start with one clear problem statement: for example, \u201cA visible upper layer appeared after cooling, but was absent in the sample collected immediately after emulsification.\u201d<\/p>\n<p class=\"wp-block-paragraph\">Then separate observations, hypotheses and the evidence needed to distinguish them.<\/p>\n<p class=\"gm-et-scroll-hint\">Swipe horizontally to view all columns.<\/p>\n<div class=\"gm-et-table\" role=\"region\" tabindex=\"0\" aria-label=\"Cream separation investigation matrix\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Observation<\/th>\n<th scope=\"col\">Questions to investigate<\/th>\n<th scope=\"col\">Evidence that helps<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A concentrated layer appears, but droplets may remain separate<\/td>\n<td>Is migration or flocculation occurring, rather than fusion?<\/td>\n<td>Comparable top and bottom samples, suitable microscopy and time-dependent droplet observations<\/td>\n<\/tr>\n<tr>\n<td>Larger droplets appear after storage<\/td>\n<td>Has the droplet population changed, and by which mechanism?<\/td>\n<td>Initial and stored size distributions, microscopy and a review of formulation and storage history<\/td>\n<\/tr>\n<tr>\n<td>Graininess develops during cooling<\/td>\n<td>Are the particles crystals, agglomerates or another structure?<\/td>\n<td>Samples across cooling stages, microscopy appropriate to the material and phase-preparation records<\/td>\n<\/tr>\n<tr>\n<td>Samples differ across the vessel<\/td>\n<td>Is circulation, ingredient incorporation or sampling responsible?<\/td>\n<td>Defined sampling locations and times, addition records and repeat sampling under an approved procedure<\/td>\n<\/tr>\n<tr>\n<td>Bubbles appear mainly after transfer or filling<\/td>\n<td>Is air being introduced downstream of the vessel?<\/td>\n<td>Matched samples before transfer, after transfer and after filling<\/td>\n<\/tr>\n<tr>\n<td>Only some filled packs change<\/td>\n<td>Do package, filling or storage differences correlate with the defect?<\/td>\n<td>Bulk retains and filled-pack retains, container records and storage-temperature history<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p class=\"wp-block-paragraph\">The table is a set of investigation prompts, not a diagnosis or proof that one condition has a single cause.<\/p>\n<p class=\"wp-block-paragraph\">A useful controlled trial states four things in advance: the hypothesis, the change being tested, the comparison sample and the acceptance criteria. Avoid changing formulation, shear, cooling and vacuum simultaneously without an experimental design; otherwise an improved result may still leave the cause unknown.<\/p>\n<p class=\"wp-block-paragraph\">An initial screening trial may isolate one factor. Where interactions are likely, a structured experimental design is more informative than repeatedly adjusting settings by intuition.<\/p>\n<h3 class=\"wp-block-heading\" id=\"gm-et-investigation-workflow\">Investigation workflow<\/h3>\n<figure class=\"gm-et-flow\" aria-labelledby=\"gm-et-flow-title\">\n<figcaption id=\"gm-et-flow-title\">Emulsion investigation workflow<\/figcaption>\n<ol class=\"gm-et-flow-steps\">\n<li><strong>1. Record the defect and retain samples<\/strong><p>Describe what changed and when it first appeared.<\/p><\/li>\n<li><strong>2. Assess the dominant evidence<\/strong><div class=\"gm-et-flow-branches\"><div><span>Bubbles<\/span><p>Review air entry and deaeration.<\/p><\/div><div><span>Layers or texture changes<\/span><p>Review formulation and process history.<\/p><\/div><\/div><p class=\"gm-et-flow-note\">If defects coexist, investigate both paths.<\/p><\/li>\n<li><strong>3. Define a hypothesis and controlled trial<\/strong><p>Set the comparison, sampling method and acceptance criteria.<\/p><\/li>\n<li><strong>4. Compare matched samples over time<\/strong><p>Follow the product through cooling, transfer, filling and storage.<\/p><\/li>\n<li><strong>5. Are the acceptance criteria met?<\/strong><div class=\"gm-et-flow-branches\"><div><span>Yes<\/span><p>Document the findings for quality review.<\/p><\/div><div><span>No or unclear<\/span><p>Revise the hypothesis and return to step 2.<\/p><\/div><\/div><\/li>\n<\/ol>\n<\/figure>\n<p class=\"wp-block-paragraph\"><em>Follow your facility\u2019s product-specific quality review and batch-release procedures when assessing the findings.<\/em><\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-confirm-the-result-beyond-the-mixing-vessel\">Assess Stability After Cooling, Filling and Storage<\/h2>\n<p class=\"wp-block-paragraph\">An improvement at discharge is a useful observation, but it is not the end of the assessment.<\/p>\n<figure class=\"gm-et-photo\">\n<img class=\"wp-image-29462\" width=\"800\" height=\"800\" loading=\"lazy\" decoding=\"async\" src=\"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe1-800x800.webp\" alt=\"GRAND CB100 100 L vacuum emulsifying mixer with the stainless steel mixing vessel tilted.\" srcset=\"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe1-800x800.webp 800w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe1-430x430.webp 430w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe1-150x150.webp 150w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe1-700x700.webp 700w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe1-300x300.webp 300w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe1-768x768.webp 768w, https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/10\/\u526f\u56fe1.webp 1000w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption><em>GRAND CB100 vacuum emulsifying mixer with the vessel tilted.<\/em><\/figcaption><\/figure>\n<p class=\"wp-block-paragraph\">Compare samples using the same preparation and measurement methods. Record temperature and sample age when measuring viscosity. For droplet measurements, use suitable sample preparation: changes introduced by dilution or handling can otherwise complicate interpretation.<\/p>\n<p class=\"wp-block-paragraph\">Track the relevant properties over time rather than relying on one average value. A mean droplet size can conceal a changing coarse-droplet population, while a single viscosity measurement cannot describe every aspect of flow behavior.<\/p>\n<p class=\"wp-block-paragraph\">Include the intended finished package and relevant storage conditions in the assessment. ANVISA\u2019s cosmetic stability guide treats formulation stability, packaging compatibility and distribution conditions as related but distinct considerations.<a href=\"#gm-et-ref-6\">[6]<\/a><\/p>\n<p class=\"wp-block-paragraph\">Accelerated or stress testing should answer a defined question. A screening result does not, by itself, establish shelf life; excessively severe conditions may introduce changes unlike those expected during normal distribution. Physical appearance also does not replace the necessary chemical or microbiological evaluations.<a href=\"#gm-et-ref-6\">[6]<\/a><\/p>\n<p class=\"wp-block-paragraph\">Finally, keep troubleshooting and batch disposition separate. A sample that looks uniform after remixing does not establish that the affected production batch is acceptable. Rework and release remain subject to your facility\u2019s quality procedures and product-specific evidence.<\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-frequently-asked-questions\">Frequently Asked Questions<\/h2>\n<style>\n.gm-faq-list{display:grid;gap:10px;margin:18px 0 30px}\n.gm-faq-item{margin:0;padding:0;border:1px solid #e0e8ed;border-radius:8px;background:#fff;overflow:hidden}\n.gm-faq-item[open]{border-color:#b8ccd9}\n.gm-faq-item summary{display:flex;align-items:center;justify-content:space-between;gap:16px;min-height:58px;padding:15px 18px 15px 20px;list-style:none;color:#253f54;cursor:pointer}\n.gm-faq-item summary::-webkit-details-marker{display:none}\n.gm-faq-item summary::marker{display:none;content:\"\"}\n.gm-faq-item summary:hover{background:#f8fafc}\n.gm-faq-item summary h3{margin:0!important;font-size:16px!important;font-weight:600!important;line-height:1.5!important;color:#253f54!important;letter-spacing:normal}\n.gm-faq-item summary::after{content:\"\";display:block;flex:0 0 28px;width:28px;height:28px;border-radius:50%;background-color:#edf3f7;background-image:linear-gradient(#24587a,#24587a),linear-gradient(#24587a,#24587a);background-position:center;background-repeat:no-repeat;background-size:12px 2px,2px 12px;transition:background-size .22s ease,background-color .22s ease}\n.gm-faq-item[open] summary::after{background-color:#e1edf5;background-size:12px 2px,2px 0}\n.gm-faq-item p{padding:0 20px 18px;margin:0!important;font-size:15px!important;line-height:1.7!important;color:#4b6072!important}\n@media(max-width:767px){.gm-faq-item summary{min-height:54px;padding:13px 14px 13px 16px}.gm-faq-item summary h3{font-size:15px!important}.gm-faq-item p{padding:0 16px 16px}}\n<\/style>\n<div class=\"gm-faq-list\">\n<details class=\"gm-faq-item\" open><summary><h3 id=\"gm-et-does-a-higher-homogenizer-speed-prevent-separation\">Does a higher homogenizer speed prevent separation?<\/h3><\/summary><p>Not necessarily. Speed influences processing, but formulation, circulation and the stage at which shear is applied also matter. A setting change should test a defined hypothesis rather than serve as a universal remedy.<\/p><\/details>\n<details class=\"gm-faq-item\"><summary><h3 id=\"gm-et-can-a-cream-separate-even-when-its-droplets-are-initially-small\">Can a cream separate even when its droplets are initially small?<\/h3><\/summary><p>Yes. Initial droplet size is only one observation. Interfacial stability, the surrounding structure and subsequent processing or storage can still affect the product.<\/p><\/details>\n<details class=\"gm-faq-item\"><summary><h3 id=\"gm-et-is-every-visible-layer-a-sign-of-coalescence\">Is every visible layer a sign of coalescence?<\/h3><\/summary><p>No. Droplets can redistribute without merging, and liquid release can have other explanations. Use observations and measurements capable of distinguishing the suspected mechanisms.<\/p><\/details>\n<details class=\"gm-faq-item\"><summary><h3 id=\"gm-et-can-a-vacuum-emulsification-mixer-guarantee-shelf-life\">Can a vacuum emulsification mixer guarantee shelf life?<\/h3><\/summary><p>No. Vacuum is a processing capability. Shelf-life conclusions require product-specific evidence across appropriate conditions and time.<\/p><\/details>\n<details class=\"gm-faq-item\"><summary><h3 id=\"gm-et-should-a-separated-cream-simply-be-mixed-again\">Should a separated cream simply be mixed again?<\/h3><\/summary><p>Not as an automatic corrective action. Remixing may change its appearance while leaving the cause unresolved. Any rework needs an approved method and quality assessment.<\/p><\/details>\n<\/div>\n<h2 class=\"wp-block-heading\" id=\"gm-et-key-takeaway\">Key Takeaway<\/h2>\n<p class=\"wp-block-paragraph\"><strong>Successful emulsification mixer troubleshooting connects formulation, droplet formation, whole-batch circulation, thermal history and downstream handling.<\/strong><\/p>\n<p class=\"wp-block-paragraph\">Identify the visible defect first. Use evidence to distinguish competing explanations. Test a controlled change, then assess whether the improvement remains meaningful after cooling, filling and storage.<\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-prepare-an-emulsification-equipment-enquiry\">Prepare an Emulsification Equipment Enquiry<\/h2>\n<p class=\"wp-block-paragraph\">If your investigation identifies a need to review mixing capacity, circulation, temperature control or deaeration, prepare these details before comparing equipment:<\/p>\n<ul>\n<li>Product type, target batch size and viscosity range at the relevant processing temperatures<\/li>\n<li>Current vessel, homogenizer and agitation arrangement, including the normal operating fill level<\/li>\n<li>The stage at which the defect appears, with photos and comparable sample observations<\/li>\n<li>Ingredient-addition sequence, mixing stages and heating\/cooling records<\/li>\n<li>Transfer and filling arrangements, available utilities and the intended equipment scope<\/li>\n<\/ul>\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cngrandmachinery.com\/contact-us\/\">Discuss your emulsification equipment requirements with GRAND<\/a>. For selection criteria, see the <a href=\"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-buying-guide\/\">emulsification mixer buying guide<\/a>; for downstream tube filling and cartoning, see the <a href=\"https:\/\/cngrandmachinery.com\/blog\/cosmetic-packaging-machine-buying-guide\/\">cosmetic packaging equipment guide<\/a>.<\/p>\n<h2 class=\"wp-block-heading\" id=\"gm-et-technical-references\">Technical References<\/h2>\n<ol>\n<li id=\"gm-et-ref-1\">Milankovi\u0107 et al. (2026; first published online in 2025). <a href=\"https:\/\/scijournals.onlinelibrary.wiley.com\/doi\/10.1002\/jctb.70118\" target=\"_blank\" rel=\"nofollow noopener\">Not Just Water: Ionic Influence on the Rheology of Natural O\/W Emulsions<\/a>. <em>Journal of Chemical Technology &amp; Biotechnology<\/em>, 101, 578\u2013589. First published online 14 December 2025. DOI: 10.1002\/jctb.70118. Formulation-specific experimental evidence.<\/li>\n<li id=\"gm-et-ref-2\">Calvo et al. (2022). <a href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0263876222004233\" target=\"_blank\" rel=\"nofollow noopener\">Effect of emulsification parameters on the rheology, texture, and physical stability of cosmetic emulsions: A multiscale approach<\/a>. <em>Chemical Engineering Research and Design<\/em>, 186, 407\u2013415. Evidence concerning processing and scale-up variables. DOI: 10.1016\/j.cherd.2022.08.011.<\/li>\n<li id=\"gm-et-ref-3\">Chow et al. (2024). <a href=\"https:\/\/pmc.ncbi.nlm.nih.gov\/articles\/PMC11207101\/\" target=\"_blank\" rel=\"nofollow noopener\">The Effect of Process Parameters on the Microstructure, Stability, and Sensorial Properties of an Emulsion Cream Formulation<\/a>. <em>Pharmaceutics<\/em>, 16(6), 773. A specific cream study, not a universal operating recipe.<\/li>\n<li id=\"gm-et-ref-4\">IKA (2023). <a href=\"https:\/\/www.ika.com\/ika\/pdf\/flyer-catalog\/20230901_LAB-Cosmetic_A4_Flyer_IWS_EN_websingle.pdf\" target=\"_blank\" rel=\"nofollow noopener\">Lab Essentials for Your Cosmetic Formulation<\/a>. Manufacturer brochure describing IKA\u2019s laboratory reactor functions, including vacuum de-foaming during mixing.<\/li>\n<li id=\"gm-et-ref-5\">Silverson. <a href=\"https:\/\/www.silverson.com\/us\/products\/batch-mixers\/\" target=\"_blank\" rel=\"nofollow noopener\">High Shear Batch Mixers: How It Works<\/a>. Manufacturer explanation of rotor\u2013stator workhead stages and batch circulation.<\/li>\n<li id=\"gm-et-ref-6\">ANVISA (2005, English edition). <a href=\"https:\/\/www.gov.br\/anvisa\/pt-br\/centraisdeconteudo\/publicacoes\/cosmeticos\/manuais-e-guias\/guia-de-estabilidade-de-cosmeticos-ingles.pdf\" target=\"_blank\" rel=\"nofollow noopener\">Cosmetic Products Stability Guide<\/a>. Background guidance on stability assessment, packaging compatibility and storage conditions.<\/li>\n<\/ol>\n<script>\n(() => {\n  const syncPreviewBreadcrumb = () => {\n    if (!document.body.classList.contains('postid-32021')) return;\n    const query = new URLSearchParams(location.search);\n    if (query.get('preview') !== 'true') return;\n    const current = document.querySelector('.gm-bp-crumb [aria-current=\"page\"]');\n    if (current) current.textContent = 'emulsification-mixer-cream-separation';\n  };\n  const afterReady = () => requestAnimationFrame(syncPreviewBreadcrumb);\n  if (document.readyState === 'loading') document.addEventListener('DOMContentLoaded', afterReady, {once:true});\n  else afterReady();\n  window.addEventListener('load', syncPreviewBreadcrumb, {once:true});\n})();\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Analyser les ph\u00e9nom\u00e8nes de s\u00e9paration de la cr\u00e8me, de granulosit\u00e9 et de formation de bulles. Comparer les donn\u00e9es relatives \u00e0 la formulation, au m\u00e9lange, au refroidissement et au conditionnement, puis utiliser un processus structur\u00e9 pour planifier le prochain essai.<\/p>","protected":false},"author":4,"featured_media":32119,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[128],"tags":[],"class_list":["post-32021","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-machine-know-how"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Emulsification Mixer Troubleshooting: Cream Separation<\/title>\n<meta name=\"description\" content=\"Troubleshoot cream emulsion separation by comparing formulation, shear, cooling, vacuum and filling. Use a clear workflow to plan controlled investigations.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cngrandmachinery.com\/fr\/blog\/emulsification-mixer-cream-separation\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Emulsification Mixer Troubleshooting: Why Cream Emulsions Separate\" \/>\n<meta property=\"og:description\" content=\"Learn why cream emulsions separate and how formulation, high-shear mixing, cooling, vacuum deaeration and storage affect stability.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cngrandmachinery.com\/fr\/blog\/emulsification-mixer-cream-separation\/\" \/>\n<meta property=\"og:site_name\" content=\"GRAND Machinery Technology\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-14T11:58:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T07:41:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/11\/cream-emulsion-separation-cover-1000.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Josie\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:title\" content=\"Emulsification Mixer Troubleshooting: Why Cream Emulsions Separate\" \/>\n<meta name=\"twitter:description\" content=\"Learn why cream emulsions separate and how formulation, high-shear mixing, cooling, vacuum deaeration and storage affect stability.\" \/>\n<meta name=\"twitter:image\" content=\"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/11\/cream-emulsion-separation-cover-1000.webp\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Josie\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"13 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/\"},\"author\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/#\\\/schema\\\/person\\\/josie\",\"name\":\"Josie\"},\"headline\":\"Emulsification Mixer Troubleshooting: Why Cream Emulsions Separate\",\"datePublished\":\"2026-11-14T11:58:47+00:00\",\"dateModified\":\"2026-11-19T07:41:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/\"},\"wordCount\":2570,\"publisher\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cngrandmachinery.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/cream-emulsion-separation-cover-1000.webp\",\"articleSection\":[\"Machine Know-how\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/\",\"url\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/\",\"name\":\"Emulsification Mixer Troubleshooting: Cream Separation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cngrandmachinery.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/cream-emulsion-separation-cover-1000.webp\",\"datePublished\":\"2026-11-14T11:58:47+00:00\",\"dateModified\":\"2026-11-19T07:41:40+00:00\",\"description\":\"Troubleshoot cream emulsion separation by comparing formulation, shear, cooling, vacuum and filling. Use a clear workflow to plan controlled investigations.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/cngrandmachinery.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/cream-emulsion-separation-cover-1000.webp\",\"contentUrl\":\"https:\\\/\\\/cngrandmachinery.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/cream-emulsion-separation-cover-1000.webp\",\"width\":1000,\"height\":1000,\"caption\":\"Two glass cosmetic jars on a stainless-steel lab workbench comparing a separated cream emulsion on the left with a smooth, uniform white cream sample on the right.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/blog\\\/emulsification-mixer-cream-separation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/cngrandmachinery.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Emulsification Mixer Troubleshooting: Why Cream Emulsions Separate\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/#website\",\"url\":\"https:\\\/\\\/cngrandmachinery.com\\\/\",\"name\":\"GRAND Machinery Technology\",\"description\":\"Processing and packaging machinery manufacturer and exporter in Wenzhou, China\",\"publisher\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/cngrandmachinery.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/#organization\",\"name\":\"GRAND Machinery Technology\",\"alternateName\":\"WENZHOU GRAND MACHINERY TECHNOLOGY CO., LTD.\",\"url\":\"https:\\\/\\\/cngrandmachinery.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/cngrandmachinery.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/\u5927\u683c\u673a\u68b0-1-scaled.webp\",\"contentUrl\":\"https:\\\/\\\/cngrandmachinery.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/\u5927\u683c\u673a\u68b0-1-scaled.webp\",\"width\":2560,\"height\":739,\"caption\":\"GRAND Machinery Technology\"},\"image\":{\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/cngrandmachinery.com\\\/#\\\/schema\\\/person\\\/josie\",\"name\":\"Josie\",\"description\":\"Josie has over 18 years of experience in the machinery industry, with in-depth knowledge of processing and packaging equipment. She specializes in tailoring equipment solutions to customers' specific production requirements.\",\"image\":\"https:\\\/\\\/cngrandmachinery.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/grand-machinery-blog-avatar.webp\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"D\u00e9pannage d'un m\u00e9langeur-\u00e9mulsificateur : s\u00e9paration de la cr\u00e8me","description":"R\u00e9solvez les probl\u00e8mes de s\u00e9paration des \u00e9mulsions cr\u00e9meuses en comparant la formulation, le cisaillement, le refroidissement, le vide et le remplissage. Utilisez un processus clair pour planifier des analyses contr\u00f4l\u00e9es.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cngrandmachinery.com\/fr\/blog\/emulsification-mixer-cream-separation\/","og_locale":"fr_FR","og_type":"article","og_title":"Emulsification Mixer Troubleshooting: Why Cream Emulsions Separate","og_description":"Learn why cream emulsions separate and how formulation, high-shear mixing, cooling, vacuum deaeration and storage affect stability.","og_url":"https:\/\/cngrandmachinery.com\/fr\/blog\/emulsification-mixer-cream-separation\/","og_site_name":"GRAND Machinery Technology","article_published_time":"2026-11-14T11:58:47+00:00","article_modified_time":"2026-11-19T07:41:40+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/11\/cream-emulsion-separation-cover-1000.webp","type":"image\/webp"}],"author":"Josie","twitter_card":"summary_large_image","twitter_title":"Emulsification Mixer Troubleshooting: Why Cream Emulsions Separate","twitter_description":"Learn why cream emulsions separate and how formulation, high-shear mixing, cooling, vacuum deaeration and storage affect stability.","twitter_image":"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/11\/cream-emulsion-separation-cover-1000.webp","twitter_misc":{"\u00c9crit par":"Josie","Dur\u00e9e de lecture estim\u00e9e":"13 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/#article","isPartOf":{"@id":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/"},"author":{"@id":"https:\/\/cngrandmachinery.com\/#\/schema\/person\/josie","name":"Josie"},"headline":"Emulsification Mixer Troubleshooting: Why Cream Emulsions Separate","datePublished":"2026-11-14T11:58:47+00:00","dateModified":"2026-11-19T07:41:40+00:00","mainEntityOfPage":{"@id":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/"},"wordCount":2570,"publisher":{"@id":"https:\/\/cngrandmachinery.com\/#organization"},"image":{"@id":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/#primaryimage"},"thumbnailUrl":"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/11\/cream-emulsion-separation-cover-1000.webp","articleSection":["Machine Know-how"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/","url":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/","name":"D\u00e9pannage d'un m\u00e9langeur-\u00e9mulsificateur : s\u00e9paration de la cr\u00e8me","isPartOf":{"@id":"https:\/\/cngrandmachinery.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/#primaryimage"},"image":{"@id":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/#primaryimage"},"thumbnailUrl":"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/11\/cream-emulsion-separation-cover-1000.webp","datePublished":"2026-11-14T11:58:47+00:00","dateModified":"2026-11-19T07:41:40+00:00","description":"R\u00e9solvez les probl\u00e8mes de s\u00e9paration des \u00e9mulsions cr\u00e9meuses en comparant la formulation, le cisaillement, le refroidissement, le vide et le remplissage. Utilisez un processus clair pour planifier des analyses contr\u00f4l\u00e9es.","breadcrumb":{"@id":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/#primaryimage","url":"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/11\/cream-emulsion-separation-cover-1000.webp","contentUrl":"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/11\/cream-emulsion-separation-cover-1000.webp","width":1000,"height":1000,"caption":"Two glass cosmetic jars on a stainless-steel lab workbench comparing a separated cream emulsion on the left with a smooth, uniform white cream sample on the right."},{"@type":"BreadcrumbList","@id":"https:\/\/cngrandmachinery.com\/blog\/emulsification-mixer-cream-separation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cngrandmachinery.com\/"},{"@type":"ListItem","position":2,"name":"Emulsification Mixer Troubleshooting: Why Cream Emulsions Separate"}]},{"@type":"WebSite","@id":"https:\/\/cngrandmachinery.com\/#website","url":"https:\/\/cngrandmachinery.com\/","name":"GRAND Technologie des machines","description":"Fabricant et exportateur de machines de transformation et de conditionnement \u00e0 Wenzhou, en Chine","publisher":{"@id":"https:\/\/cngrandmachinery.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cngrandmachinery.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/cngrandmachinery.com\/#organization","name":"GRAND Technologie des machines","alternateName":"WENZHOU GRAND MACHINERY TECHNOLOGY CO., LTD.","url":"https:\/\/cngrandmachinery.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cngrandmachinery.com\/#\/schema\/logo\/image\/","url":"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/08\/\u5927\u683c\u673a\u68b0-1-scaled.webp","contentUrl":"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/08\/\u5927\u683c\u673a\u68b0-1-scaled.webp","width":2560,"height":739,"caption":"GRAND Machinery Technology"},"image":{"@id":"https:\/\/cngrandmachinery.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/cngrandmachinery.com\/#\/schema\/person\/josie","name":"Josie","description":"Josie poss\u00e8de plus de 18 ans d'exp\u00e9rience dans le secteur des machines et dispose d'une connaissance approfondie des \u00e9quipements de transformation et de conditionnement. Elle est sp\u00e9cialis\u00e9e dans la conception de solutions d'\u00e9quipement sur mesure, adapt\u00e9es aux besoins de production sp\u00e9cifiques des clients.","image":"https:\/\/cngrandmachinery.com\/wp-content\/uploads\/2026\/11\/grand-machinery-blog-avatar.webp"}]}},"_links":{"self":[{"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/posts\/32021","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/comments?post=32021"}],"version-history":[{"count":7,"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/posts\/32021\/revisions"}],"predecessor-version":[{"id":32118,"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/posts\/32021\/revisions\/32118"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/media\/32119"}],"wp:attachment":[{"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/media?parent=32021"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/categories?post=32021"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cngrandmachinery.com\/fr\/wp-json\/wp\/v2\/tags?post=32021"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}